Modbus RTU to Siemens S7 PLC

Connect Modbus RTU Slave Devices Directly to the Data Table of your Siemens S7 PLC.

460MMSC

$896.72$1,251.75

SKU: 460MMSC

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Get Your Modbus RTU Slave Devices Connected Directly to the Data Table of your Siemens S7 PLC

Connect your Modbus RTU to Siemens S7 PLC Gateway with the 460MMSC. The 460MMSC connects 32 Modbus RTU Slave devices to up to 5 Siemens S7 PLCs. This product is Made in the USA, is always in stock, and includes a 5-year warranty.

How do I use 460MMSC in my application?

When you’re connecting a Modbus RTU to a Siemens S7 PLC Gateway firstly, allocate two memory blocks in your Siemens S7 PLC. One block is for a user-defined set of Output addresses that send data to your Modbus RTU Slaves. The other block is for Input-only data that receives data from your Modbus RTU Slaves. It’s really that simple. If you need to modify your data as it transfers between protocols, it’s easy to do so. You can apply up to 3 mathematical functions to each data mapping. For example, you can add 4 to a value, multiply by 4, and divide by 10 with ease.

For more gateway solutions check out our Solutions for Allen-Bradley PLCs page.

Why Use Real Time Automation as a Gateway Supplier?

While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from Real Time Automation. When you call us, a live person answers the phone. If you talk with our sales team, you will get honest answers and recommendations. And rest assured, all the support you get is from an engineer who had a hand in the product’s development, and support doesn’t need a ticket or 24-hour wait. We get back to you as soon as possible. It’s an RTA promise.

Modbus RTU Client Features

Modbus Operation Modes: Modbus RTU Client
Function Codes Supported: 1, 2, 3, 4, 5, 6, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus RTU Client Devices: 32
Number Read/Write Scan Lines per RTU Server Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 125 Registers or 512 Coils

S7 Client Features

PLC Support: S7 300/400/1200/1500
Maximum Number of PLCs Supported: 5
Maximum Number of Inputs per PLC: 150
Maximum Number of Outputs per PLC: 150
Array Support: Yes, for all data types
Supported Data Types: 8Bit Int, 16Bit Int, 32Bit Int, 32Bit Float, Bool and String

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.