Connect EtherNet/IP Adapter Devices to an Allen-Bradley PLC

Easily connect up to 32 EtherNet/IP devices to a Allen-Bradley PLC

460ECETC

$896.72$979.31

SKU: 460ECETC

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Get Your EtherNet/IP Adapters Connected Directly to the Data Table of Your Legacy Allen-Bradley PLCs

The 460ECETC moves data between up to 32 EtherNet/IP Adapter devices and up to 5 AB PLCs.

Have an Allen-Bradley PLC that doesn’t support Ethernet/IP? Move data from your EtherNet/IP Adapter devices to low level legacy Allen-Bradley PLCs like the Micrologix, SLC 500, and PLC5E. Need to limit the number of EtherNet/IP connections to your ControlLogix or CompactLogix? The 460ECETC does not require an EtherNet/IP connection.

Best of all the product is Made in the USA, is always in stock and comes with 5 year warranty.

How Does the Data Move In and Out of the Allen-Bradley PLC?
You allocate two areas of register blocks in your Allen-Bradley PLC. One area is a user defined set of write only registers accepting data from your EtherNet/IP devices. The other area is full of read only register blocks to send data to your EtherNet/IP devices. You directly map EtherNet/IP data into read and write locations in the data table of your MicroLogix PLC.

It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions.

Why Use Real Time Automation as a Gateway Supplier?
The 460ECETC provides an option to access EtherNet/IP Adapter devices without having to upgrade your PLC or get an expensive in-rack solution. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us.

Try the RTA difference today and give us a call at 1-800-249-1612.

Ethernet/IP Scanner Features

Operation Modes: Class 1 I/O Scanner (minimal Adapter is required and supported)
Message Support: Implicit Class 1 Cyclic I/O, Explicit not supported
Data Types: BIT8,16 & 32; INT8, 16, 32 & 64; UINT8,16, 32 & 64; Float & Double
Maximum EtherNet/IP Adapter Devices: 32
Max Data Per Adapter Connection: Up to 496 bytes in each direction

EtherNet/IP Tag Client Features

PLC Support: ControlLogix, CompactLogix, FlexLogix, MicroLogix, SLC’s and PLC5E’s
Maximum Number of PLCs Supported: 5
Maximum Number Read Tags or Registers Supported: 150 per PLC
Maximum Number Write Tags or Registers Supported: 150 per PLC
Array Support: Yes, for all data types except strings
Supported Data Types: ControlLogix / CompactLogix / FlexLogix: Bit, 32 Bit Array, SINT, INT, REAL, STRING, DINT, MicroLogix / SLC / PLC5E: 16 Bit Array, INT, REAL, STRING

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.

Happy Holidays! Our office will be closed Wednesday 12/25/24. Orders placed after 2 pm CST 12/24/24 will be processed 12/26/24.