Connect BACnet MS/TP Devices to an Allen-Bradley PLC

Easily connect up to 32 BACnet MS/TP devices to up to 5 Allen-Bradley PLCs with the 460ETCBM.

460ETCBM

$896.72$1,251.75

SKU: 460ETCBM

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Connect Allen-Bradley PLCs to BACnet MS/TP Subordinates

The 460ETCBM moves data between up to 32 BACnet MS/TP devices and 1-5 Allen-Bradley PLCs. With the 460ETCBM you are making a direct connection between BACnet MS/TP objects and user defined Tags or Registers in the data table of your Allen-Bradley PLC. There is no polling from the PLC or Ethernet/IP scan lists to arrange. This is a direct connection between your device data and the data table of your PLC.

How Does the Data Move In and Out of the PLC?

You allocate two areas of tags or register blocks in your Allen-Bradley PLC. One area is a user defined set of write only tags or register blocks accepting data from BACnet MS/TP. The other area is full of read only tags or register blocks to send data to your BACnet MS/TP devices. You directly map BACnet MS/TP Analog and Binary data into read and write locations in the data table of your Allen-Bradley PLC.

For more gateway solutions check out our Solutions for Allen-Bradley PLCs page.

Why Use Real Time Automation as a Gateway Supplier?

The 460ETCBM provides an option to access a BACnet MS/TP system with an Allen-Bradley PLC without an expensive in-rack solution. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA. When you call, a live person answers the phone. If you talk with sales, you will get honest answers and recommendations even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us.

BACnet MS/TP Manager Features

BACnet/ MS/TP Operation Modes: BACnet MS/TP Manager Initiator
Supported Object Types: Device, Binary, Analog, Multi-State, Character String Value
Supported Service Codes: Read Property-A, Read Property Multiple-A, Write Property-A, Write Property
Multiple-A, Device Dynamic Binding-A
Maximum Connections: 32
Number Read/Write Scan Lines per Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 128 Total Objects

EtherNet/IP Tag Client Features

PLC Support: ControlLogix, CompactLogix, FlexLogix, MicroLogix, SLC’s and PLC5E’s
Maximum Number of PLCs Supported: 5
Maximum Number Read Tags or Registers Supported: 150 per PLC
Maximum Number Write Tags or Registers Supported: 150 per PLC
Array Support: Yes, for all data types except strings
Supported Data Types: ControlLogix / CompactLogix / FlexLogix: Bit, 32 Bit Array, SINT, INT, REAL, STRING, DINT, MicroLogix / SLC / PLC5E: 16 Bit Array, INT, REAL, STRING

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.

Attn: Our office is closed November 28-29 in observance of Thanksgiving. Orders placed after 2 pm CST 11/27/24 will be processed 12/2/24.