INTRAVUE
IntraVUE is a production control network diagnostic monitoring tool that empowers plant personnel to shift from a reactive to a proactive approach to significantly improve both the uptime and performance of critical, plant floor Ethernet networks.

IntraVUE Scanner Software
IntraVUE is the diagnostic tool for non-network experts diagnosing problems in Ethernet factory floor control networks.
Learn moreIntraVUE Scanner Appliance
IntraVUE is the diagnostic tool for non-network experts diagnosing problems in Ethernet factory floor control networks.
Learn moreIntraVUE Agent
Designed to work with the IntraVUE Scanner, this tool provides effortless visibility into EtherNet/IP and PROFINET I/O networks
IntraVUE Scanner Features
- Designed for non-network experts to monitor and diagnose production control networks
- View network status on a live, color-coded topology map
- Immediate notice when a new device joins your production network
- Generate and export an asset list for every device on your network
- Display an event log capturing the activities for every device on your network
- View daily or 30-day KPIs for network and all critical swiches and devices
- No changes to your product control network required
IntraVUE Agent Features
- Live color-coded topology view of all your I/O networks
- Capture EtherNet/IP and PROFINET device faults
- Capture intermittent network events
- Alert on new foreign device connections
- Identify failing switches, cables and devices
- Get I/O network asset reports
- Capture network activity for later review
- View VLAN devices
What Our Customers Are Saying

You guys are great! BTW we just dodged a bullet!!! IntraVUE sent out email alerts that we were having ping failures on a machine and we didn’t
see any issues but when we looked into the NIC… it failed… but we were ready and swapped it out losing no downtime!!! NOW if you can tell me
when the operator is going to fail we can swap that person out in a timely manner too!!! Thx.

I just wanted to let you know that IntraVUE just saved me an 80-mile roundtrip to the plant on a Saturday night just to change-out an Ethernet
PLC module. Since I was able to quickly identify the issue by simply looking at the live IntraVUE network status I just had one of our onsite
employees swap out the module. And since I had an adult beverage or two in me, IntraVUE also helped to keep the highways safer tonight.
Product specifications for the IntraVUE Scanner Appliance and IntraVUE Agent | |
---|---|
Power | 8 -24 VDC (22W Max) |
Device Memory | Up to 128 GB LPDDR4 on CM4 |
Temp Range | -20°C to 60°C (Humidity: 10-95% non-condensing) |
Certifications | RoHS, UL, CE approvals |
Top I/O Ports | 2 USB 2.0 ports, 1 USB 3.2 gen 1 Port, USB-C port (CM4 mgmt) 1 reset button |
Bottom I/O Ports | 2 1GbE LAN, 3-pin terminal block power 1 RS-232/422/485 5-pin terminal block |
Mounting | Din rail |
Physical Attributes for the IntraVUE Scanner Appliance and IntraVUE Agent