Connect BACnet MS/TP Subordinate to DH+ Devices

Connects up to 32 BACnet MS/TP Subordinates with as many as 32 DH+ devices

460BMDHM

$1,495.00$1,510.75

SKU: 460BMDHM

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Control up to 32 BACnet MS/TP Devices from a Serial PLC5 or SLC PLC

You can now control a network of 32 BACnet MS/TP devices from a legacy Allen-Bradley serial PLC. It’s the perfect tool to save legacy PLCs from the scrap pile and control BACnet MS/TP devices directly from the serial port of PLC5s and SLCs. You can now extend the function of the legacy PLCs your already have.

How Do I Use the 460BMDHM-D2E in My Application?

PLC data table values (File like N7:200 and F9:1) are mapped directly into analog and binary values. Input files from your legacy PLC are passed to the BACnet MS/TP devices. Output data received from BACnet MS/TP is written to your legacy PLC data table. No message instructions and no ladder. It really is that simple

What Is BACnet and What It Can Do for You?

Discover whether BACnet/IP aligns with your specific needs. Check out our BACnet tech page – BACnet is a communications protocol that defines the services used to communicate between building automation end-devices and building control systems. It has an open architecture with the ability to control and monitor any building automation process.

Why Use Real Time Automation as a Gateway Supplier?

While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from Real Time Automation. When you call us, a live person answers the phone. If you talk with our sales team, you will get honest answers and recommendations. And rest assured, all the support you get is from an engineer who had a hand in the product’s development, and support doesn’t need a ticket or 24-hour wait. We get back to you as soon as possible. It’s an RTA promise.

DH+ Features

Operation Mode: DH+ Master
PLCs Supported: 5/04, PLC5
Maximum Devices Supported: 32
Scan Lines: 100 input / 100 output
Supported Data Types: 100 Integers or 100 Binaries, or 50 floats, 82 character string per Scan line

BACnet MS/TP Manager Features

BACnet/ MS/TP Operation Modes: BACnet MS/TP Manager Initiator
Supported Object Types: Device, Binary, Analog, Multi-State, Character String Value
Supported Service Codes: Read Property-A, Read Property Multiple-A, Write Property-A, Write Property
Multiple-A, Device Dynamic Binding-A
Maximum Connections: 32
Number Read/Write Scan Lines per Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 128 Total Objects

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.

Attn: Our office is closed November 28-29 in observance of Thanksgiving. Orders placed after 2 pm CST 11/27/24 will be processed 12/2/24.