BACnet MS/TP Controller to OPC UA

Get Your BACnet MS/TP Controllers connected to OPC UA

460BMSUS

$896.72$1,251.75

SKU: 460BMSUS

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Get Your BACnet MS/TP Controllers connected to OPC UA

The 460MBSUS connects a BACnet MS/TP system and up to 3 OPC Clients.

Best of all the product is Made in the USA, is always in stock and comes with 5 year warranty.

How do I use 460BMSUS in my application?

Incoming and outgoing BACnet MS/TP analog and binary data is mapped to OPC nodes. The data moves bidirectionally.

It’s really that simple to convert data to the information systems you need to monitor your application.

Why Use Real Time Automation as a Gateway Supplier?

While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

BACnet MS/TP Slave Features

BACnet/ MS/TP Operation Modes: BACnet MS/TP Master Responder
Supported Object Types: Device, Binary I/O, Analog I/O, Character String Value
Supported Service Codes: Read & Read Multiple-B, Write & Write Multiple-B, COV & COV unsolicited-B, Device Dynamic Binding, Dynamic Object Binding-B, Device Communication Control-B
Maximum Connections: 1
Analog Objects: Supported 1200 Input and 1200 Output
Binary Objects: Supported 1600 Input and 1600 Output

OPC UA Server Features

Operation Mode: opc.tcp/binary with no Security
Simultaneous Connections Supported: 3
Max Number of Input Nodes per Node Type: 200
Max Number of Output Nodes per Node Type: 200
Array Support: Boolean, Integer, Unsigned Int and Float
Profiles Supported: UA 1.03 Micro Embedded Server and Data Access

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.

Attn: Our office is closed November 28-29 in observance of Thanksgiving. Orders placed after 2 pm CST 11/27/24 will be processed 12/2/24.