Connect DH+ Serial PLCs to Ethernet Based Allen- Bradley PLCs

Connects up to five Allen-Bradley PLCs with as many as 32 DH+ devices

460ETCDHM

$1,495.00$1,510.75

SKU: 460ETCDHM

INCLUDES
PRODUCT FEATURES
DATASHEETS & USERGUIDES

Easily Connect Data Tables in Your Legacy PLC to tags in Logix Processors

There is no easier way to transfer data between any of your Ethernet-based Allen-Bradley PLCs and legacy serial Allen-Bradley PLCs! PLC5 or SLC5/04 can now provide inputs to a Logix processor and get outputs from a Logix processor. It’s the perfect tool to keep those old legacy PLCs from the scrap pile and extend their useful life.

How Do I Use the 460ETCDHM-D2E in My Application?

For most applications, the mapping is very straightforward. PLC file locations (like N7:200 and F9:1) are mapped directly to tags in your Logix processor. No message instructions and no ladder is need to transfer the data. The gateway pushes and pulls the data from defined file and tag blocks. It really is that simple.

Which Allen-Bradley Gateway Is Right For You?

You’ll find our current family of Allen-Bradley gateways on our Allen-Bradley PLC solutions page – We also have connectivity solutions for your legacy A-B PLCs. Find what you’re looking for.

Why Use Real Time Automation as a Gateway Supplier?

While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from Real Time Automation. When you call us, a live person answers the phone. If you talk with our sales team, you will get honest answers and recommendations. And rest assured, all the support you get is from an engineer who had a hand in the product’s development, and support doesn’t need a ticket or 24-hour wait. We get back to you as soon as possible. It’s an RTA promise.

DH+ Features

Operation Mode: DH+ Master
PLCs Supported: 5/04, PLC5
Maximum Devices Supported: 32
Scan Lines: 100 input / 100 output
Supported Data Types: 100 Integers or 100 Binaries, or 50 floats, 82 character string per Scan line

EtherNet/IP Tag Client Features

PLC Support: ControlLogix, CompactLogix, FlexLogix, MicroLogix, SLC’s and PLC5E’s
Maximum Number of PLCs Supported: 5
Maximum Number Read Tags or Registers Supported: 150 per PLC
Maximum Number Write Tags or Registers Supported: 150 per PLC
Array Support: Yes, for all data types except strings
Supported Data Types: ControlLogix / CompactLogix / FlexLogix: Bit, 32 Bit Array, SINT, INT, REAL, STRING, DINT, MicroLogix / SLC / PLC5E: 16 Bit Array, INT, REAL, STRING

What our Customers are Saying

“I challenged a customer to get it working by the time I got back from his break room with a Coke and he indeed had it working when I got back. He then said, "It’s worth twice the price!"”

Eric P. / Kendall Electric

“Everything seems to be working as we imagined. Thanks for the great response time. I did not see any way to save the configuration other than screen shots, but the configuration did not get lost in the update. Thanks again, and you were a pleasure to work with.”

Kevin L. / Extol, Inc.

Attn: Our office is closed November 28-29 in observance of Thanksgiving. Orders placed after 2 pm CST 11/27/24 will be processed 12/2/24.